{% set baseFontFamily = "Open Sans" %} /* Add the font family you wish to use. You may need to import it above. */

{% set headerFontFamily = "Open Sans" %} /* This affects only headers on the site. Add the font family you wish to use. You may need to import it above. */

{% set textColor = "#565656" %} /* This sets the universal color of dark text on the site */

{% set pageCenter = "1100px" %} /* This sets the width of the website */

{% set headerType = "fixed" %} /* To make this a fixed header, change the value to "fixed" - otherwise, set it to "static" */

{% set lightGreyColor = "#f7f7f7" %} /* This affects all grey background sections */

{% set baseFontWeight = "normal" %} /* More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set headerFontWeight = "normal" %} /* For Headers; More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set buttonRadius = '40px' %} /* "0" for square edges, "10px" for rounded edges, "40px" for pill shape; This will change all buttons */

After you have updated your stylesheet, make sure you turn this module off

Berk-Tek's Converged Application Score

by Paige Looney on October 15, 2015

CA_Banner

Over 15 years ago when the Cat 6 standards were developed, transmitting data from computer to computer was the norm. Today, file sizes are exponentially larger and we are starting to transmit a lot more voice, data, video, and power simultaneously to many different IP devices. Knowing that just meeting the Cat 6 minimum might not be enough anymore, Berk-Tek has pioneered a new way ensure your network can handle the stress of current and future network demands by measuring network infrastructure performance through the Converged Application (CA) Score.

The Converged Application Score Test Process

CA_Score_Test

What Coverged Application Scores Mean

The CA Score is based on applications-based tests that measure how well cables perform under the stress of real-world applications such as VoIP, IP video, and power. This propriety algorithm combines several tests that are performed over a specially designed 100-meter four-connector channel. The CA score ranges from 1 to 10, with a score of 10 being the best. A low CA Score means that there were consistent noticeable flaws (dropped frames, media loss, etc) in the applications tested. For example, VoIP calls would usually sound choppy, streaming video would have regular interruptions (many per hour) in both audio and visual quality, and files would take longer to open. Higher scores mean there were fewer flaws. PoE testing is also an important factor; cables that experience less temperature rise achieve higher CA Scores.

CAScore_515x55_1

 

Find Out More About Coverged Application Scores

For more information about Berk-Tek's Converged Application Scores, download the CA Score Guide below:

 

CA_Guide

 

Download CA Score Guide

 

unnamed-5

Find Out More About The TEK Center

Located at Berk-Tek's headquarters in New Holland, PA, The TEK Center is the premier showcase for emerging applications in data center and enterprise environments. The TEK Center specialists can customize the data center display to help you determine which option bets fits your needs. Learn More

To find out more about Berk-Tek's solutions for your facility or next installation, or for any other questions, please contact your local Accu-Tech representative.

Topics: Cat 6A Berk-Tek cable testing