{% set baseFontFamily = "Open Sans" %} /* Add the font family you wish to use. You may need to import it above. */

{% set headerFontFamily = "Open Sans" %} /* This affects only headers on the site. Add the font family you wish to use. You may need to import it above. */

{% set textColor = "#565656" %} /* This sets the universal color of dark text on the site */

{% set pageCenter = "1100px" %} /* This sets the width of the website */

{% set headerType = "fixed" %} /* To make this a fixed header, change the value to "fixed" - otherwise, set it to "static" */

{% set lightGreyColor = "#f7f7f7" %} /* This affects all grey background sections */

{% set baseFontWeight = "normal" %} /* More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set headerFontWeight = "normal" %} /* For Headers; More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set buttonRadius = '40px' %} /* "0" for square edges, "10px" for rounded edges, "40px" for pill shape; This will change all buttons */

After you have updated your stylesheet, make sure you turn this module off

Tripp Lite's Row-Based Cooling Solutions

by Nate Johnson on June 12, 2014

SRCOOL33K-FRONT-L-1

For large scale data center facilities, achieving a stable temperature set point across every row of cabinets and servers is absolutely critical to maintaining optimal efficiency. Temperature fluctuations and equipment overheating are very real threats to your systems integrity, which are compounded by today's expanding high-density applications. Tripp Lite offers a series of row-based air conditioning units to provide this additional cooling, which can also provide a host of other benefits beyond providing top-notch cold-aisle containment – such as being protected from circuit overloads and voltage spikes, or their self-contained design so that no floor drains or additional infrastructure is needed for the installation!

 

The flagship for Tripp Lite's cold aisle row-based air conditioning system is the SRCOOL33K 33,000 BTU energy-saving air conditioning unit. This variable-speed DC-inverter driven compressor is equipped with an electronic expansion valve to enable precision cooling adjustments – for quiet, efficient cycling to meet just the cooling level your facility may need at any given time, nothing more, nothing less. The soft start feature limits inrush current and voltage disruptions, and the self-contained unit re-humidifies condensation, expelling it through the exhaust air stream – so no extra piping, drains or infrastructure is required to be installed. The slick easy-to-read LCD screen provides local management and control options, and for remote management capabilities, a Modbus interface is available – sure to please remote managers or IT personnel looking to receive alerts, access logs, or make settings/security changes.

 

To learn more about the SRCOOL33K, take a read through this white paper courtesy of Tripp Lite, or scroll down to see the key features:

 

Key Features

  • 33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption

  • Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling adjustments--no more wasteful, noisy cycling between off and full blast

  • Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads

  • Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air stream--no floor drain, water collection tank, external condenser, refrigerant piping, duct work or plumbing required

  • Convenient LCD control panel and network interface provide local and remote monitoring and control of temperature, humidity, fan speed, alarms and logging via front-panel buttons, SNMP, Web, telnet/SSH or Modbus

  • Row-based airflow path maximizes hot-aisle/cold-aisle efficiency and cooling predictability by supplying cold intake air high in the cold aisle and removing hot equipment exhaust air high in the hot aisle

  • Includes a standard heavy-duty L6-30P input plug for easy installation - no electrician needed

  • RoHS compliance and R410A refrigerant meets environmental standards worldwide

  • 200-240V AC Input, 50/60 Hz frequency compatibility

 