{% set baseFontFamily = "Open Sans" %} /* Add the font family you wish to use. You may need to import it above. */

{% set headerFontFamily = "Open Sans" %} /* This affects only headers on the site. Add the font family you wish to use. You may need to import it above. */

{% set textColor = "#565656" %} /* This sets the universal color of dark text on the site */

{% set pageCenter = "1100px" %} /* This sets the width of the website */

{% set headerType = "fixed" %} /* To make this a fixed header, change the value to "fixed" - otherwise, set it to "static" */

{% set lightGreyColor = "#f7f7f7" %} /* This affects all grey background sections */

{% set baseFontWeight = "normal" %} /* More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set headerFontWeight = "normal" %} /* For Headers; More than likely, you will use one of these values (higher = bolder): 300, 400, 700, 900 */

{% set buttonRadius = '40px' %} /* "0" for square edges, "10px" for rounded edges, "40px" for pill shape; This will change all buttons */

After you have updated your stylesheet, make sure you turn this module off

Use a HARP to Improve Energy Efficiency in Data Centers and Server Rooms

by Katy Plant on August 31, 2021

HARP, also known as Hot Aisle Return Plenum, will be featured in this blog post that nVent HOFFMAN provided in order to show how the principles of physics can help to  lower energy costs and CO2 emissions dramatically: 


pexels-scott-webb-305833About 20-60% of energy costs in data centers are consumed by cooling the system down, forcing operators to heavily invest in new hardware. In order to meet the requirements of a continuously rising data load, servers have recently become more powerful, therefore requiring higher density racks. As the amount of processed data increases, so does the temperature in the server racks; as the technical requirements for cooling in the server rooms increase, so do their costs.

How it works
The HARP is a containment solution that separates hot air from cold air. It directs the hot air to the back of the rack, then upward to a ceiling plenum where it is directed to a facility cooling unit.

This unit channels the cooled air back into the ambient air of the data center, where it is drawn into the racks from the front. It flows through the rack and on its way to the back, the cooled air removes heat from the system and maintains a perfect ambient temperature for the installed electronics. Then, it is pushed back into the hot aisle as warm air to repeat the cycle.

HARP Features
• Channels hot air into CRAC/CRAH units (Computer Room Air Condition / Computer Room Air Handler), preventing hot and cold air from mixing

• Pairs with existing aisle containment doors like 600mm, 750mm, 800mm and 1200mm wide panels – custom sized panels are also available

• Manufactured to fit the cabinet and facility ceiling height

• Pairs with ProLine Aisle Containment sliding doors
AdobeStock_350460499


For such an installation, nearly any premise is suitable. There is no need for expensive architectural environments, such as a false floor for air circulation, a prerequisite for cold aisle cooling.

HARP Benefits at a Glance
• Drastically reduces energy costs

• Reduces data center carbon footprint

• Quick and simple installation with only two tools (3mm and 8mm Allen keys)

That’s it- By directing airflow in a controlled manner, as well as separating hot air from cold air, operators can dramatically reduce their data center energy costs and quickly create a positive ROI.

Sound interesting? Contact your local Accu-Tech Representative today to learn more about nVent HOFFMAN's product line, or visit their vendor page here. 

 

Topics: energy efficiency data center cooling nvent